Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Gradient High Performance Liquid Chromatography Method Development and Validation for Simultaneous Determination of Phenylephrine and Ibuprofen in Tablet Dosage Form

Venkata Raveendra Babu Vemula1 , Pankaj Kumar Sharma2

1Faculty of Pharmacy, Pacific Academy of Higher Education and Research University, Udaipur-313024; 2School of Pharmaceutical Sciences, Jaipur National University, Jaipur-302025, Rajasthan, India.

For correspondence:-  Venkata Vemula   Email: raveendra.vemula@gmail.com   Tel:+9705126244

Received: 16 June 2013        Accepted: 17 March 2014        Published: 26 June 2014

Citation: Vemula VR, Sharma PK. Gradient High Performance Liquid Chromatography Method Development and Validation for Simultaneous Determination of Phenylephrine and Ibuprofen in Tablet Dosage Form. Trop J Pharm Res 2014; 13(6):967-974 doi: 10.4314/tjpr.v13i6.21

© 2014 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To develop a gradient high performance liquid chromatography (HPLC) method for the simultaneous determination of phenylephrine (PHE) and ibuprofen (IBU) in solid dosage form.
Methods: HPLC determination was carried out on an Agilent XDB C-18 column (4.6 x 150mm, 5 μ particle size) with a gradient mobile phase composed of 0.1 % orthophosphoric acid and acetonitrile at a ratio of: 0.01/95/5, 2.5/95/5, 6/10/90, 8/10/90, 8.1/95/5 and 13/95/5 for time (min)/0.1 % orthophosphoric acid (%)/acetonitrile (%)  at a flow rate of 1.0 mL/min. Column temperature was maintained at 30 °C and detection was carried out using a photodiode array (PDA) detector at 210 nm. Validation parameters, including system suitability, linearity, precision, accuracy, specificity, limit of detection (LOD), limit of quantification (LOQ), stability of sample and standard stock solutions as well as robustness were obtained as per International Conference on Harmonization (ICH) guidelines. The proposed method was applied to the determination of phenylephrine and ibuprofen in commercial tablets.
Results:  Retention time for phenylephrine and ibuprofen were 2.7 and 8.4 min, respectively while % recovery was 99.42 and 99.80 %, respectively. The relative standard deviation (% RSD) for assay of the tablets was < 2 %.
Conclusion: The method is fast, accurate, precise and sensitive, and hence it can be employed for routine quality control of tablets containing both drugs in quality control (QC) laboratories and pharmaceutical industry.

Keywords: Phenylephrine, Ibuprofen, Simultaneous determination, Validation, Gradient HPLC

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates